A Finite Element Analysis of a Biodegradable Cervical Plate and Screw System
Jaeyon Choi, Lihua Che, Keung Nyun Kim, Seong Yi, Yoon Ha, Do Heum Yoon, Dong Ah Shin
Department of Neurosurgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
Correspondence:  Dong Ah Shin, Tel: +82-2-2228-2174, Fax: +82-2-393-9979, 
Email: cistern@yuhs.ac
Abstract
Objective
To evaluate a biodegradable cervical plate and screw system by 3D modeling and finite element analysis.
Methods
The authors are developing a biodegradable cervical plate and screw system using poly-L-lactic acid (PLLA). A computational model was evaluated before experimenting it into humans. The system was fabricated using 3D modeling and analyzed with finite element analysis using a commercially available software (Abaqus 6.4, Simulia, USA). Compression and bending tests were performed by applying a force of 100 N to the screw to analyze the applied von Mises stress. The screw and plate were combined, and a force of 100 N was applied to the screw to analyze the von Mises stress on the screw and plate.
Results
When a bending force of 100 N was applied to the distal 1/3 part of the screw, widening of the head and anchor of the screw, bending of approximately 20°, and concentration of von Mises stress at the pin were observed. These phenomena indicate the possibility of head and anchor fractures when severe loading is applied. When a compressive force of 100 N was applied to the screw in the plate and screw combined model, concentration of von Mises stress at the blocking parts of the plate. The phenomenon indicate the possibility of plate fracture when severe loading is applied.
Conclusion
Because biodegradable material is weak, biomechanical weakness may result in breakage of a system. According to our research, two parts of screw should be combine into one and the plate design also be modified without weak points.
Key Words: Biodegradable materials; Spinal implant; Finite element analysis; Biomechanics; Anterior cervical discectomy and fusion
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 1 Crossref
  •    
  • 2,249 View
  • 18 Download
Related articles in Asian J Pain


ABOUT
ARTICLE CATEGORY

Browse all articles >

BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
Department of Neurosurgery, Korea University College of Medicine
73, Goryeodae-ro, Seongbuk-gu, Seoul 02841, Korea
Tel: +82-2-920-5729    Fax: +82-2-929-0629    E-mail: ajp.editor.in.chief@gmail.com                

Copyright © 2024 by Korean Neuro-Pain Society.

Developed in M2PI

Close layer
prev next